I. Introduction HR-083 Series Mirror gloss instrument to its technical parameters in full compliance with national standard GB9754-88, GB9966.5 and international standard Quasi ISO2831, the performance indexes reach the national JJG696-2002 (Mirror to gloss instrument metrological verification) a work For aircraft requirements.
Second, application 1, paint, ink, paint, paint, wood products such as surface gloss measurement. 2, building decoration materials: marble, granite, vitrified tiles, ceramic tiles and other surface gloss measurement. 3, plastic, paper, etc. Measurement of the surface gloss. 4, other non-metallic surface gloss measurement. 3, apparatus, characterized by 1, fine, lightweight form factor, easy to carry. 2, all-intelligent design, one-touch operation, easy to use. 3, automatic calibration, no need to hand-tune when the beep prompt attention to the sample must be formed. 4, long-life light source, without changing 5, measurement accuracy, good repeatability. 6, LCD digital display. 7, the operation process has buzzing sound prompts. 8, with a power supply under-voltage indicator. 9, has an automatic shutdown.
4, technical parameters Measuring range: 0-200GU Stability: less than ± 0.4% GU/30Min Indication error: less than ± 1.2GU Power Supply: 1.5V Power Supply Projection angle: 20 ℃ / 60 ℃ / 85 ℃ Ambient temperature: 0-40 ℃ Relative humidity: not more than 85% Calibration board size: 90 × 40MM
5, display reading CU gloss units CAL OK Calibration Tips MES said that measuring state SELECT angle selection tips Baattery Lo battery voltage at the end, suggesting that changing the battery 6, use the method 1, press the power switch "POWER" LCD screen showing the evidence that he has connected to the power, instruments to work. 2, apparatus prompts "calibration operation" display shows "CAL?" For instrument calibration window alignment calibration plate, Click the "OP" key to confirm the calibration operation, calibration of automatic identification instrument panels, and automatically complete the calibration of instrument calibration Device has beep prompt. 3 to complete the calibration operation, apparatus into the measurement of the state, the sample will be tested on the instrument to measure the window alignment measured Pieces, press the yellow button, instruments began to measure, the completion of measurement, the display shows the measured values of the surface gloss, With a variety of point of view, arbitrary choice. (Separable type) 4, apparatus can be manually turned off, click the "POWER" instrument is turned off, the display without any display, If the measuring instrument for 5 minutes of operation, automatic shutdown devices. 5, measurement instruments displayed on the screen: 2:? ? 6,? ? 8:? ? (Respectively 20 ℃ 60 ℃ 85 ℃)
7, pay attention to matters 1, the use of direct glare should be avoided, otherwise affect the measurement accuracy. 2, apparatus equipped with a standard board should be kept clean, do not touch the surface with your fingers, surface stains, impact measurement of quasi - Indeed sexual, available lens cleaning cloth or anhydrous alcohol 3, the battery runs out, apparatus, prompted the battery voltage, the display shows "Battery Lo" the need to replace batteries, open the Measuring surface battery cover, remove the battery replacement, pay attention to cable polarity, the battery runs out should be immediately replaced, otherwise, keep a long time Put, the old battery charge may be fluid flow, resulting in damage to equipment, apparatus, not a long time, should remove the battery. |